AC interference on pipelines: why it happens and how mitigation works

Shared corridors put pipelines next to high-voltage lines. Here is what induced AC does, and what zinc ribbon, grounding mats and decouplers do about it.

RCS Technical Team

Roberts Corrosion Services, Harrisville, WV

Spool of zinc ribbon on a pipeline right of way
Spool of zinc ribbon on a pipeline right of way. Photo: Roberts Corrosion Services.

Key takeaways

  • Induced AC creates two risks: shock hazard at above-ground appurtenances and AC corrosion on the pipe.
  • Zinc ribbon and grounding mats bleed AC to earth and control touch and step voltage.
  • Solid state decouplers pass AC to ground while blocking DC, so cathodic protection keeps working.

Pipelines and power lines like the same routes: long, straight, already cleared. When a buried pipeline runs parallel to a high-voltage AC line, the magnetic field around the conductors induces a voltage on the pipe. Well-coated pipe makes this worse, because the coating insulates the steel from the soil that would otherwise drain the AC away.

Two problems, not one

  • Safety. Anyone touching a test station, valve or rectifier can be exposed to dangerous touch voltage. Industry practice (NACE SP0177) uses 15 V AC as the threshold for action at accessible points.
  • AC corrosion. At small coating holidays, high AC current density can corrode steel even when DC cathodic protection meets criteria.

The mitigation toolkit

ComponentWhat it does
Zinc ribbonBuried alongside the pipe as a gradient control wire, giving induced AC a low-resistance path to earth along the run.
Grounding matsPlaced at test stations, valves and other above-ground appurtenances to equalize the ground surface and cut touch and step voltage.
Solid state decouplers (SSD)Connect the pipe to the grounding system for AC while blocking DC, so CP current is not lost to ground.
Pedestals and splice kitsProtect and join connections so the system stays continuous for years.
AC mitigation materials RCS keeps in stock.

Design starts with measurement

Effective mitigation is tailored to site conditions: soil resistivity, the power line loading and geometry, and the pipeline's coating and route. Mitigation that is not measured after installation is a guess, so inspection and periodic monitoring are part of the job.

RCS installs zinc ribbon and grounding mats on existing facilities and new construction, inspects third-party installations for placement, continuity and grounding effectiveness, and documents the results for PHMSA and industry standards.